A pharmacy CLIA-waived testing program organizes procedures, training and records for patient testing. The pharmacy needs a certificate appropriate to its tests or CLIA-exempt status, plus applicable authority for pharmacist ordering and treatment. Integral Healthcare Solutions (IHS) drafts documents for the owner and clinical lead to approve. IHS is a consulting firm, not a law firm, and this page is not legal advice.
Last updated: November 2026
What is a CLIA-waived testing program in a pharmacy?
This page covers pharmacy services using waived test systems under a Certificate of Waiver and the manufacturer's instructions; CLIA-exempt laboratories follow their applicable state program. CDC lists pharmacies among the waived testing sites it addresses (CDC Waived Tests, page opened November 26, 2026). CDC also says waived tests include test systems cleared by the FDA for home use and those approved for waiver under the CLIA criteria.
The federal rules sit in 42 CFR Part 493. Section 493.15 sets the criteria for a waived test: cleared for home use, so simple and accurate that erroneous results are negligible, or posing no reasonable risk of harm if performed incorrectly. HHS decides which tests meet them, and FDA keeps the Currently Waived Analytes list. Under 493.15(e) a laboratory eligible for a certificate of waiver must follow the manufacturers' instructions for performing the test and meet the requirements of subpart B. Section 493.35 requires a separate application per location unless paragraph (b) applies. An owner signs, or an authorized representative signs and attests to operation under the Secretary's requirements in section 353 of the Public Health Service Act. Section 493.37 makes the certificate valid for no more than two years and requires the laboratory to permit announced or unannounced HHS inspections in accordance with subpart Q. Section 493.39 requires notice to HHS or its designee within 30 days of a change in ownership, name, location or director. All four were read in current text on November 26, 2026 (Title 42 last amended October 8, 2026).
CLIA certification does not itself authorize pharmacist ordering or treatment; applicable state and federal authority must be checked. Iowa shows how one state does it: Iowa Code 155A.46 lets a pharmacist order and administer prescription drugs, products, tests or treatments under statewide protocols that the Board of Pharmacy approves with the state health department, and the Board posts protocols on its statewide protocols page (opened November 26, 2026). Its influenza protocol sets patient eligibility, consent, training, referral and treatment conditions; age alone does not establish eligibility. Your state may differ on every point, so the program starts with your board of pharmacy.
Who needs this program and what triggers it?
A pharmacy needs it when it will test patients on site without a certificate that fits its test menu, or when it will add a test to a certificate it already holds. Common starting points are a new rapid-test service, a new location, a change of owner or director, or a state rule or protocol that opens a testing service to pharmacists. Federal PREP Act provisions can also affect pharmacist authority; this page does not assess eligibility for their protections (12th Amendment, page opened November 26, 2026).
How does Integral Healthcare Solutions help build the program?
IHS is a firm with three practice lines: accreditation consulting, compliance services and program development. This work sits in program development, with Thomas G. Goddard, JD, PhD, IHS founder and former URAC Chief Operating Officer and General Counsel, leading it. IHS reviews the planned tests and locations against 42 CFR Part 493 and the state authority the client identifies, maps each requirement to a procedure and a record, drafts what is missing for the pharmacy's clinical lead to approve, and runs a mock review of the finished records against the checklist below.
What IHS drafts: test-by-test procedure shells that point to the manufacturer's instructions; a policy that keeps testing inside the Certificate of Waiver; patient-flow and specimen-labeling procedures; training and competency record templates; a results and referral procedure; quality logs for storage, expiration dates and lot changes; a change-notice procedure for the 30-day rule; and an exposure control plan outline for the pharmacy's safety lead. Where the state uses a protocol for pharmacist ordering, IHS drafts the pharmacy-side procedures that fit it, for the pharmacy and its counsel to approve.
What you supply: the owner or authorized representative who signs Form CMS-116, the laboratory director, your test list and the manufacturers' instructions for each product, your state authority and any prescriber arrangement, staff records, and your own legal advice on state law.
The real limit: IHS does not choose tests clinically, perform or supervise testing, decide whether a pharmacist may order or treat, or interpret state law for you. Under 493.1840(a)(2), CMS may initiate certificate action if an owner, operator or employee performs, or represents entitlement to perform, procedures outside the certificate's category. Under 493.37(d), failure to meet subpart B requirements results in certificate and Medicare/Medicaid payment sanctions under subpart R's procedures.
What should a pharmacy have ready?
Gather these before the first working session. CFR references below use current text opened November 26, 2026: Title 42 last amended October 8, 2026; Title 29 last amended November 9, 2026.
- Your test menu and each specific test system's waived status (FDA Currently Waived Analytes and linked test systems, page opened November 26, 2026).
- Current manufacturer instructions for each test (42 CFR 493.15(e)).
- Testing addresses and any applicable multiple-location exception (493.35(a)-(b)).
- The owner signing, or authorized representative signing and attesting to operation under the Secretary's section 353 requirements (493.35(c)(2)).
- Your laboratory director; CMS sets no federal education or experience qualifications for a waiver director (CMS Apply for a CLIA Certificate, page opened November 26, 2026).
- Your applicable ordering and treatment authority and required training; Iowa's statewide protocols illustrate state-specific conditions, not nationwide rules (page opened November 26, 2026).
- A procedure for notifying HHS or its designee of ownership, name, location or director changes within 30 days (493.39(b)), and returning the prescribed renewal application 9–12 months before expiration while meeting 493.35 and 493.37 (493.37(f)).
- A written plan to eliminate or minimize exposure if employees have occupational exposure as defined in 29 CFR 1910.1030(b), (c)(1)(i).
- Documented practice under an experienced observer before patient testing; CDC recommends this in Ready? Set? Test! (July 2026; page opened November 26, 2026). Some recommendations exceed waived-testing CLIA requirements.
- A procedure keeping tests and sample preparation within the waived system's manufacturer instructions (493.15(e)).
The free introductory call is where IHS walks through this list with you.
How does a Certificate of Waiver compare with other certificate types?
A Certificate of Waiver covers waived tests only; other certificate types allow nonwaived testing. CMS says all certificate types allow waived testing and applicants use the type matching their highest test complexity (CMS Apply for a CLIA Certificate, page opened November 26, 2026). A registration certificate lasts no more than two years or until inspection, whichever is shorter, and is not renewable (493.45(e), current text opened November 26, 2026).
| Certificate | Testing allowed | Routine surveys, per CMS |
|---|---|---|
| Certificate of Waiver | Waived tests only | No routine surveys; a complaint can bring an unannounced one |
| Certificate for provider-performed microscopy | Listed microscopy personally performed during the patient's visit by a qualifying practitioner under 493.19(b), including its patient-relationship and supervision/state-authorization conditions, plus waived tests | No routine surveys; same complaint rule |
| Compliance or accreditation | Nonwaived moderate and high complexity testing, plus waived tests | Survey every two years by CMS, the State Agency or an approved accreditation organization |
Source for the table: the CMS CLIA Certification brochure, revised November 2026, page opened November 26, 2026. A pharmacy that adds nonwaived tests moves to a different program; the IHS CLIA laboratory certificate start-up page covers that path.
What does CLIA waived testing cost to start?
CMS publishes certificate fees by certificate type in its CLIA Certificate Fee Schedule (marked updated 2024; page opened November 26, 2026), and its Apply page says you receive a fee notification by email after you submit Form CMS-116 and then pay through pay.gov. CMS also says to contact your State Survey Agency for the specific fees your laboratory pays. Verify current fees with CMS or your State Agency. IHS scopes each engagement after a free introductory call.
What is this program not?
It is not legal advice, and it is not a statement of what your state allows. It is not a guarantee that a certificate will issue or that a complaint inspection will go well. IHS does not file with, contact or correspond with CMS, a State Agency or a board of pharmacy; your owner signs and files, and your pharmacy communicates with them. It is not a clinical protocol.
Frequently asked questions
Does a pharmacy need a CLIA certificate to run a rapid test?
Generally yes for patient testing, unless the laboratory is CLIA-exempt under 42 CFR 493.3. For the federal waiver route, submit Form CMS-116 to the State Agency, pay the fee and receive the certificate before testing. Additional state requirements also apply.
What does a Certificate of Waiver allow a pharmacy to do?
It allows waived tests and no others, and under 42 CFR 493.15(e) the laboratory must follow the manufacturer's instructions for each test. CDC says any off-label use of a test system is considered high-complexity testing under CLIA.
Does the pharmacist have to be the laboratory director?
CLIA does not say so. CMS states that a Certificate of Waiver laboratory must have a laboratory director and that there are no federal education or experience qualifications for that director. States may add rules.
Will CMS inspect a waived pharmacy laboratory?
Not routinely. CMS says a Certificate of Waiver laboratory is not subject to routine surveys, but a complaint can bring an unannounced survey, and 42 CFR 493.37(b)(2) requires the laboratory to permit announced or unannounced HHS inspections in accordance with subpart Q.
Can a pharmacist order a flu or strep test and prescribe treatment?
CLIA certification alone does not authorize ordering or prescribing. Iowa Code 155A.46 provides for statewide protocols developed and approved by the Board of Pharmacy in consultation with the Department of Health and Human Services. The applicable protocol controls the permitted services, qualifications and conditions; other states differ.
What happens if the pharmacy adds a test that is not waived?
Before performing or reporting a nonwaived test outside its certificate, the pharmacy must notify HHS or its designee under 493.39(a) and obtain the appropriate certificate. CMS requires reapplication on Form CMS-116, payment of any additional fees and receipt of the updated certificate before using the new certificate type.
Do staff need an OSHA exposure control plan?
If employees have occupational exposure as defined in 29 CFR 1910.1030(b), the employer must establish a written Exposure Control Plan designed to eliminate or minimize exposure. Assess reasonably anticipated job-related contact with blood or the other potentially infectious materials defined there; specimen collection alone does not determine coverage.
Does Integral Healthcare Solutions apply for the certificate or contact the State Agency?
No. IHS drafts the documents; the pharmacy submits them and communicates with the authorities. Under 493.35(c)(2), an owner signs the application, or an authorized representative signs and attests that the laboratory will operate under the Secretary's requirements in section 353 of the Public Health Service Act.